Segment
X12 EDI Release 00504
To report individual animal test results
Elements
  • ATR011607Test Type Code
    ID
    M必须(Mandatory)

    Code identifying the type of test performed for which measured results will be reported

    Codes (20)
  • ATR021313Test Period or Interval Value
    N
    M必须(Mandatory)
    Min 1 / Max 6

    Numeric value of period or interval signifying when a test event occurs

  • ATR03344Unit of Time Period or Interval
    ID
    M必须(Mandatory)

    Code indicating the time period or interval

    Codes (60)
  • ATR04739Measurement Value
    R
    O可选(Optional)
    Min 1 / Max 20

    The value of the measurement

  • ATR05C001Composite Unit of MeasureO可选(Optional)
    35510186493551018649355101864935510186493551018649
    • ATR0501355Unit or Basis for Measurement Code
      ID
      M必须(Mandatory)

      Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken

      Codes (884)
    • ATR05021018Exponent
      R
      O可选(Optional)
      Min 1 / Max 15

      Power to which a unit is raised

    • ATR0503649Multiplier
      R
      O可选(Optional)
      Min 1 / Max 10

      Value to be used as a multiplier to obtain a new value

    • ATR0504355Unit or Basis for Measurement Code
      ID
      O可选(Optional)

      Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken

      Codes (884)
    • ATR05051018Exponent
      R
      O可选(Optional)
      Min 1 / Max 15

      Power to which a unit is raised

    • ATR0506649Multiplier
      R
      O可选(Optional)
      Min 1 / Max 10

      Value to be used as a multiplier to obtain a new value

    • ATR0507355Unit or Basis for Measurement Code
      ID
      O可选(Optional)

      Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken

      Codes (884)
    • ATR05081018Exponent
      R
      O可选(Optional)
      Min 1 / Max 15

      Power to which a unit is raised

    • ATR0509649Multiplier
      R
      O可选(Optional)
      Min 1 / Max 10

      Value to be used as a multiplier to obtain a new value

    • ATR0510355Unit or Basis for Measurement Code
      ID
      O可选(Optional)

      Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken

      Codes (884)
    • ATR05111018Exponent
      R
      O可选(Optional)
      Min 1 / Max 15

      Power to which a unit is raised

    • ATR0512649Multiplier
      R
      O可选(Optional)
      Min 1 / Max 10

      Value to be used as a multiplier to obtain a new value

    • ATR0513355Unit or Basis for Measurement Code
      ID
      O可选(Optional)

      Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken

      Codes (884)
    • ATR05141018Exponent
      R
      O可选(Optional)
      Min 1 / Max 15

      Power to which a unit is raised

    • ATR0515649Multiplier
      R
      O可选(Optional)
      Min 1 / Max 10

      Value to be used as a multiplier to obtain a new value

  • ATR061608Non-Numeric Test Value
    AN
    O可选(Optional)
    Min 1 / Max 30

    Identifies a non-numeric value for a test result

  • ATR07352Description
    AN
    O可选(Optional)
    Min 1 / Max 80

    A free-form description to clarify the related data elements and their content

  • ATR081073Yes/No Condition or Response Code
    ID
    O可选(Optional)

    Code indicating a Yes or No condition or response

    Codes (4)
  • ATR09752Surface/Layer/Position Code
    ID
    O可选(Optional)

    Code indicating the product surface, layer or position that is being described

    Codes (109)
  • ATR10337Time
    TM
    O可选(Optional)
    Min 4 / Max 8

    Time expressed in 24-hour clock time as follows: HHMM, or HHMMSS, or HHMMSSD, or HHMMSSDD, where H = hours (00-23), M = minutes (00-59), S = integer seconds (00-59) and DD = decimal seconds; decimal seconds are expressed as follows: D = tenths (0-9) and DD = hundredths (00-99)