Segment
X12 EDI Release 00701
To represent sampling frequency changes or values that are conditional on measurements made on previous samples, related manufacturing stages, or the environment
Elements
  • CSF01C001Composite Unit of MeasureM必须(Mandatory)
    35510186493551018649355101864935510186493551018649
    • CSF0101355Unit or Basis for Measurement Code
      ID
      M必须(Mandatory)

      Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken

      Codes (903)
    • CSF01021018Exponent
      R
      O可选(Optional)
      Min 1 / Max 15

      Power to which a unit is raised

    • CSF0103649Multiplier
      R
      O可选(Optional)
      Min 1 / Max 10

      Value to be used as a multiplier to obtain a new value

    • CSF0104355Unit or Basis for Measurement Code
      ID
      O可选(Optional)

      Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken

      Codes (903)
    • CSF01051018Exponent
      R
      O可选(Optional)
      Min 1 / Max 15

      Power to which a unit is raised

    • CSF0106649Multiplier
      R
      O可选(Optional)
      Min 1 / Max 10

      Value to be used as a multiplier to obtain a new value

    • CSF0107355Unit or Basis for Measurement Code
      ID
      O可选(Optional)

      Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken

      Codes (903)
    • CSF01081018Exponent
      R
      O可选(Optional)
      Min 1 / Max 15

      Power to which a unit is raised

    • CSF0109649Multiplier
      R
      O可选(Optional)
      Min 1 / Max 10

      Value to be used as a multiplier to obtain a new value

    • CSF0110355Unit or Basis for Measurement Code
      ID
      O可选(Optional)

      Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken

      Codes (903)
    • CSF01111018Exponent
      R
      O可选(Optional)
      Min 1 / Max 15

      Power to which a unit is raised

    • CSF0112649Multiplier
      R
      O可选(Optional)
      Min 1 / Max 10

      Value to be used as a multiplier to obtain a new value

    • CSF0113355Unit or Basis for Measurement Code
      ID
      O可选(Optional)

      Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken

      Codes (903)
    • CSF01141018Exponent
      R
      O可选(Optional)
      Min 1 / Max 15

      Power to which a unit is raised

    • CSF0115649Multiplier
      R
      O可选(Optional)
      Min 1 / Max 10

      Value to be used as a multiplier to obtain a new value

  • CSF021167Sample Selection Modulus
    R
    O可选(Optional)
    Min 1 / Max 6

    To specify the sampling frequency in terms of a modulus of the Unit of Measure, e.g., every fifth bag, every 1.5 minutes

  • CSF03942Sample Frequency Value per Unit of Measurement Code
    N
    O可选(Optional)
    Min 1 / Max 9

    The number of samples collected